66
AVENTICS | ED05 | R414002533–BAL–001–AG
Assembling the ED05 pressure regulator
2
1
2
1
3
7
Tabelle 7:
Rectangular X1S plug, form C
Pin 1
Pin 2
Pin
Rectangular X2A plug, form C
00125291
Pin 1
Pin 2
Pin 3
00125292
Pin
1)
X1S
The
Make sure before connecting the plug that all seals and
connections are included and not damaged.
Only use tested plugs and cables.
Protect the supply voltage with an external M 1.6 A fuse.
For devices with an integrated XPC plug, M12:
Use a shielded cable to connect the XPC.
The shield must be connected to the plug housing.
Connect the cable at the integrated XPC (7) plug.
The ED05 pressure regulator can now be supplied with
00126344
voltage and controlled with a set point.
ED05 pressure regulator with two rectangular plugs
1)
EN 175301-803
0 V
24 V DC
Functional grounding (FE)
0 V
Set point (+): current 0/4 to 20 mA or
voltage 0 to 10 V DC
Actual value (+): current 0/4 to 20 mA or
voltage 0 to 10 V DC or
10 V DC constant
Functional grounding (FE)
X2A
pin 1 and
pin 1 contacts are connected internally.