Do not install, remove, or reinstall the unit by yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
For installation, always contact the dealer or an Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property da-
mage, product failure, and personal injury.
Install the unit securely in a place which can bear the weight of the unit.
Do not install the unit in a place where a flammable gas leaks.
- - - - - - - - - - - - - - - - - - - - - - - - - - -
2.1.1 - Minimum room area in the case of refrigerant gas load as per technical data label
(without additional load)
Model
MONO
2.2 - CHECKS TO PERFORM BEFORE INSTALLATION
a. Checks at the area
Before starting to work on the systems containing inflammable refrigerants, safety
checks are necessary to reduce the risk of ignition to a minimum.
to repair a refrigeration system, the following precautions must be complied with
before working on the system.
b. Work procedure
the job must be performed according to a controlled procedure in a way to reduce
the risk of the presence of inflammable gas or vapour to a minimum during the
performance of the job.
c. General work area
all maintenance personnel and those working in the local area, must be trained
regarding the job performed.
Do not work in tight spaces.
the area around the work area must be isolated.
Guarantee that the conditions inside the area are safe by verifying the inflammable
material.
Quantity
of refrigerant gas
(kg)
0,55
0,55
Height of
installation
(m)
1,8
0,6
Minimum
room area
(m
)
2
2
4
EN - 11
ARYAL S1 E