Descargar Imprimir esta página

Helo Rocher 70 Pure Instalación Y Manual De Uso página 44

Calentador de sauna eléctrico:
Ocultar thumbs Ver también para Rocher 70 Pure:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Installation and User Manual Rocher Pure
2.15. Locating the connecting box for the connection cable in the sauna room
A = Specified minimum safety clearance
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box must be
clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and regulations of the
local energy supplier.
3.
2.
Figure 5 Location for the connection box
2.16. Remote controlling
The Heater can be remotely controlled by connecting a closed contactor, which can be pulse triggered, to connectors 3
and 4 of a RJ10 circuit board. The recommended cable size is AWG 24 or 26. The maximum length of an AWG 24 cable is 200
m when using a Pure controller.
The maximum length of an AWG 26 cable is 130 m when using a Pure controller.
Note! The sauna standard requires a door switch if the sauna heater is controlled from outside the sauna.
An indicator light can be connected to the remote button terminal, it will be lit up when the remote command is activated.
The indicator light shows an error by blinking rapidly, this error is caused by keeping the sauna door open for more than
5 minutes, the sauna heater will be shut down automatically.
The remotely operated sauna heater stays on as long as the setting in the control panel (in private us max 6h). The
sauna heater can be shut off at any time by the remote-control device.
2.17.
Order of RJ 10 connectors
NOTE: Incorrect connections may break a circuit board.
Additional sensor (NTC)
Pin 1
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
Sensor (Sec/NTC)
Pin 1
End stop
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
End stop
Table 3 Coupling order of RJ 10 connectors
to circuit board
A
A
3.
2.
Remote control switch (Ext switch)
Pin 1
3.3 V
Pin 2
CPU
Pin 3
Pin 4
GND
3.3 V
CPU
10V
1
To switch
GND
To switch
12 VDC
Control panel RJ 10
connectors
Figure 6 Order of RJ 10 connectors. Sensor, Door switch, Remote
control, Additional NTC
Door switch
Pin 1
Pin 2
Alarm LED
GND
Pin 3
Door
GND
switch
Pin 4
Door
12 VDC
switch
11

Publicidad

loading

Este manual también es adecuado para:

Rocher 105 pure1102-70-040511 1102-105-040511