Configuring the coverage pattern
Remove blinders (Figure 6, item 1) if necessary. The
modified pattern is shown in Figure 6, items 3 to 7.
Note:
If both blinders are installed, the detector range is
limited to 6 m (default).
Modify the pattern by breaking out blinder parts (shown as
gray in Figure 6, item 1). The corresponding curtain
fragments are shown in Figure 6, item 2.
Put the appropriate mirror stickers if necessary. See
Figure 8, item 1 for details.
Caution:
Removing stickers can damage the mirror
surface.
When near objects directly under the detector, fit the mask
to the inside of the window (default). This disables the part
of the curtains looking down at the object, whose
closeness might destabilize the detector. See Figure 8,
item 2.
LED indication
Continuously on
Fast blinking (4 Hz)
PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm) Apply correct voltage
PIR intruder
Open (Alarm) Automatically after 3 s
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
P/N 146278999-2-ML • REV L • ISS 29MAR21
Normal blinking (1 Hz)
To reset
Automatically after 25 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to
Night mode
Open
Do a successful
(Alarm)
walk test
VE1016
VE1016AM
PIR
PIR + AM
V2E
16 m (52 ft. 6 in.)
9 high-density mirror curtains
No
9 to 15 V
(12 V nominal)
Peak-to-peak ripple
Detector start-up time
Normal current consumption
Current consumption in alarm
Maximum current consumption
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper
AM relay characteristic
Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Regulatory information
Manufacturer
Product warnings
and disclaimers
European Union
directives
REACH
Yes
VE1016
2 V (at 12 V )
25 s
5.5 mA
1.1 mA
11 mA
1.8 to 3.0 m
(5.9 to 9.8 ft.)
30 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
80 mA, 30 V
Optional
−10 to +55°C (+14 to 130°F)
108 × 60 × 46 mm
(4.25 × 2.36 × 1.81 in.)
95% max.
120 g (4.2 oz.)
IP30 IK02
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see firesecurityproducts.com or
www.aritech.com.
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
VE1016AM
60 s
10 mA
3.8 mA
24 mA
2.0 to 3.0 m
(6.6 to 9.8 ft.)
20 cm/s to 3 m/s
(8 in./s to 10 ft./s)
80 mA, 30 V
On-board (Yes)
80 mA at 30 V
max.
3 s
128 g (4.5 oz.)