Important! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in
position on the sink.
3.
Slide the fixation piece including the washer over
the threaded pins and tighten the nuts.
4.
If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter
blue marked copper pipe. (97554000)
5.
Connect the shorter, blue marked supply pipe to the
angle valve. Connect the longer blue marked pipe
to the inlet and the red marked to the outlet of the
storage tank. (see page 4)
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
Water escaping bels ow handle
Highest possible water pressure at
user's site in Mpa
0,1 – 0,15
0,2 – 0,3
0,4 – 0,7
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
10
All manuals and user guides at all-guides.com
Cause
- Spray former calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- Cartridge defective
Table for the throttle hose lengths to be used
8, 10 and 15 liters
without throttle hose
Throttle hose shortened to 90 mm
English
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Important!
With water heaters of 5 liters the flow rate at the mixer
should not exceed 5 l/min.
In this case the flow rate must be reduced at the isolation
valve.
When the storage tank is being heated, the spout will
drip.
When changing the spray former, it is imperative to use
one made for this type of mixer.
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Spare parts (see page 3)
Device content
Throttle hose unchanged
Adjust flow volume at corner valve *
max. 1 MPa
0,1 - 0,5 MPa
max. 80° C
65° C
max. 5 l/min
Remedy
- Clean spray former, exchanging if
necessary
- Exchange cartridge
- Exchange cartridge
- Exchange cartridge
up to 5 liters
Throttle hose shortened to 90 mm
Throttle hose unchanged