Installation
Step 8: Check Installation
Refer to Installer Checklist on the back cover and
make sure that unit is installed correctly.
Moving Unit to a New Location
Disconnect washer from electrical supply.
To prevent damage while moving the unit, the
shipping materials MUST BE reinstalled.
Reinstallation of Shipping Materials
Remove front access panel by removing two screws.
Place the shock sleeves on all four shock absorbers.
Refer to Figure 14.
Insert hooked end of shipping brace into the open slot
of the motor mount. Attach with bolts and lockwashers.
Refer to Figure 14.
Reinstall front access panel.
4
3
1
Shock Sleeves
2
Motor Mount
3
Bolts and Lockwashers
4
Hooked End of Shipping Brace
Figure 14
Refer to step 5 for proper procedures whenever the
unit is moved.
12
1
2
H336I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Requirements
(120 Volt, 60 Hertz with 3-Prong Grounding Plug)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code, ANSI/
NFPA No. 70, and such local regulations as
might apply. It is the customer's
responsibility to have the wiring and fuses
checked by a qualified electrician to make
sure the laundry room has adequate
electrical power to operate the washer.
DO NOT OVERLOAD
CIRCUITS
DO NOT USE AN
ADAPTER
DO NOT USE AN
EXTENSION CORD
Figure 15
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 Ampere fuse, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 16
to determine correct polarity of the wall receptable.
W227
D009I
800971