4. Operations
Program
Code
Function
Battery Type
04
(cont. from
pg. 15)
Bulk Charge
05
Voltage
Floating Charge
06
Voltage
07
AC Charger
08
PV Charger
09
Charger Priority
Low Voltage
10
Alarm
Low Voltage
11
Shutdown
Voltage point to
battery mode
when under
12
"SBU" Battery
First priority is
configured in
Program 01
AC Input
13
Voltage Range
Selectable Options
User-Defined
24V Model Default
Setting: 28.0
24V Model Default
Setting: 27.0
10A (Default)
60A (Default)
Solar and Utility
(Default)
Utility First
Solar First
22.0V (Default)
21.0V (Default)
27.0V (Default)
Appliance (Default)
UPS
Description
If "User-Defined" is selected, the battery charge voltage
and low DC cut-off voltage can be set up in program 05,
06.
Bulk charge voltage:
24V model:(default 28.0V DC)
Setting range: 24V to 30V
setting increase or decrease of 0.1V per click.
Note: User-defined should be selected in Program 04 if changes
to bulk charge voltage are needed.
Floating charge voltage:
24V model: (default 27.0V DC) Setting range: 24V to 30V
setting increase or decrease of 0.1V per selection.
Note: User-defined should be selected in Program 04 if changes
to float charge voltage are needed
2kW model: 30A.
3kW model: 45A.
The PV Charger default setting is 60A. PV setting range
from 00-60A with 10A incremental selections.
Solar and Utility will charge the battery system at the
same time.
Utility will charge the battery system as first priority. Solar
energy will assist in charging the battery only if utility
power is not available.
Solar power will charge the battery system as first priority.
Utility will charge battery system only if solar power is not
available.
Low Voltage Alarm: The LVA setting range is 18V to 25V
with 0.1V incremental selections.
Low Voltage Shutdown: LVS setting range is 18V to 25V
with +/-0.1V incremental selections.
AC cut-off point: The setting range is 20-29V with +/-0.1V
incremental selections.
If selected, the acceptable AC input range is 154-264V
AC.
If UPS is selected, the acceptable AC input voltage range
is 194-254V AC.