Installation planning
WARNING
Risk of severe injuries or death by electric shock.
Protective measures for swimming ponds:
Only use electrical units or installations with a rated voltage of U ≤ 12 V in the water.
Electrical installations with a rated voltage of U > 12 V must be located at a distance of at least
2 m from the water
WARNING
Due to the high weight of the unit, spinal injuries or crushing of limbs is possible when carrying
the unit. The unit weighs more than 25 kg.
Have at least four people carry the container exclusively on the handles to avoid spinal inju-
ries.
Protect your limbs from crushing injuries.
Do not transport the container when it is filled with water.
Electrical components of the filter system operate with a rated voltage of U
voltage is supplied via an external transformer connected to the mains.
Filter system with UVC clarifier fitted:
– The filter system and transformer must be located at a distance of at least 2 m from the
water.
Filter system without UVC clarifier fitted:
– The filter system can be installed directly next to the water. The transformer must be lo-
cated at a distance of at least 2 m from the water.
Optimum operating results can be obtained with careful planning, taking the ambient conditions
into account.
As the filter is very heavy when filled, it must be placed on a suitable base (at least on slabs,
but preferably on a poured concrete base) to prevent it from subsiding.
Align the base slab horizontally.
Ensure sufficient room for movement for carrying out cleaning and maintenance work.
Allow the dirty water to drain out into a drain or far enough away from the pond to ensure
that it cannot flow back into the pond.
Do not position the inlet into the pond higher than the outlet of the filter system (e.g. above a
water course or waterfall).
A water course or waterfall guarantees optimum water return to the pond.
In this way, the filtered pond water is enriched with oxygen before it is returned to the
pond.