14. Replace the front panel. When refitting the exterior front panel, align the 2 metal upper pegs on the heater with holes in the
exterior panel. Push the top up into place and push the bottom in, then refit the screws.
15. Refit the front outlet grill along with the screws.
RELOCATION
WARNING: Relocation to another location must be carried out by an experienced technician.
If during reinstallation the thermal insulation shows any sign of damage, it must be removed and replaced by an identical part.
MANUALLY RESET TEMPERATURE LIMITER
This heater employs a manually reset temperature limiter (see LR in the connection diagram).
This safety device operates when high temperatures are reached at the top of the heater. It requires re-setting manually:
Let the heater cool. The cause of overheating should be investigated.
WARNING: Re-setting manually must be carried out only by an experienced technician.
Turn off the heater at the circuit breaker.
Take off the front panel by removing the two screws located at the bottom. Find the limiter LR in the connection diagram and
push the small pin until a click is heard.
19