Movement
Command
ID
0X02
Retract
0x04
Extend
0x05
Stop
0x06
Operation
If the power is turned off for more than
10 seconds and then on again, 1x sound
is emitted.
The host sends an ID command via 485
to the Controller within 10 seconds.
After the controller has received the
command it stores the ID and controls
the return of the response signal to the
host. A tone will then sound 5 times.
This completes the operation
It is possible to set the stop points. Please request the instructions for this procedure from
your specialist dealer or directly via www.celexon.com.
Example
485-A:55 00 00 00 00 02 05 ID0 ID1 ID2 ID3
crcH crcL
485-B:AA ID0 ID1 ID2 ID3 02 01 crcH crcL
485-A:55 ID0 ID1 ID2 ID3 04 02 crcH crcL
485-B:AA ID0 ID1 ID2 ID3 04 01 crcH crcL
485-A:55 ID0 ID1 ID2 ID3 05 02 crcH crcL
485-B:AA ID0 ID1 ID2 ID3 05 01 crcH crcL
485-A:55 ID0 ID1 ID2 ID3 06 01 crcH crcL
485-B:AA ID0 ID1 ID2 ID3 06 01 crcH crcL