Indication Without Connection Of The Activation Of A Solenoid Valve; Technical Specifications; Electrical Characteristics - Chauvin Arnoux C.A 6609 Manual De Instrucciones

Comprobador de sentido de motor y rotación de fases
Ocultar thumbs Ver también para C.A 6609:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
8. INDICATION WITHOUT
CONNECTION OF THE ACTIVATION
1.
There must be no lead connected to the instrument;
2.
Place the instrument as close as possible to the solenoid
valve;
3.
Press the ON button. The green indicator indicates that the
instrument is in operation;
4.
The clockwise or anticlockwise rotation indicator lights,
indicating the presence of the field generated during the
activation.

9. TECHNICAL SPECIFICATIONS

9.1

ELECTRICAL CHARACTERISTICS

Maximum rated voltage:
Operating voltage, in phases rotation use:
With connections:
Without connection:
Frequency of operation:
Test current (per phase):
Power supply:
Consumption less than 20mA.
L1, L2, L3 lights are on , since 100V voltage between phases and
neutral.
24
OF A SOLENOID VALVE
600V, CAT III
40 to 600VAC between phases (see
§ 5.1 and 7)
120 to 400V
§ 6)
15 to 400Hz
less than 3.5mA
9V battery (6LR61, 6LF222, 1604A,
NEDA 1604)
between phases (see
AC