RECEPTACLES
120/240 Volt AC, 30 Amp,
Locking
Receptacle
Use a N EMA LI4-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 7).You can use the same 4-wire cord if you
_lan to run a 120Volt load.
120 Volt AC, 20 Amp,
Duplex
Receptacles
Each receptacle (Figure 8) is protected against overload by
a 20 Amp push-to-reset circuit breaker.
4-Wire Cord Set
Y (Hot)
X (H_)
Ground
NEMA L14=30
(Green)
This receptacle powers 120/240Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts of power at
30 Amps for 120Volts; 5,500 watts of power (5.5 kW) at
30 Amps for 240Volts.The outlet is protected by a 20 Amp
push-to-reset
circuit breaken
_,
AUTION!
Although this outlet states it has a
120/240 Volt 30 Amp rating (up to 7,200 watts), the
generator is only rated for 5,500 watts. Powering
loads that exceed the wattage/amperage
capacity of
the generator can damage it or cause serious injuries.
Use each receptacle to operate 120Volt AC, single-phase,
60 Hz electrical loadsrequiring up to 2,400 watts (2.4 kW)
at 20Amps of current. Use cord sets that are rated for
125Volt AC loadsat 20 Amps (or greater).
/
8