If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
OFFSET = 20
90
85
80
70
60
50
40
30
20
20
10
Adjustments from remote timer control
A
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accord-
ing to that given in table 1.
Table. 1
Heating temperature setting
DHW temperature adjustment
Summer/Winter Changeover
Eco/Comfort selection
Sliding Temperature
66
90
85
80
70
60
50
40
30
20
20
10
fig. 13 - Compensation curves
10
9
8
7
6
5
4
3
2
1
0
-10
-20
fig. 14 - Example of parallel compensation curve shift
Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
Summer mode has priority over a possible Remote Timer Control heating
demand.
On disabling DHW from the Remote Timer Control menu, the boiler selects
the Economy mode. In this condition, the button fig. 1detail 7 - on the boiler
panel is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler selects
the Comfort mode. In this condition it is possible select one of the two modes
with the button detail 7 - fig. 1.
Both the Remote Timer Control and the boiler card manage Sliding Tempera-
ture adjustment: the boiler card Sliding Temperature has priority.
cod. 3540R880 - 01/2009 (Rev. 00)