4.4 Technical data table
The column on the right gives the abbreviation used on the dataplate.
Data
Max. heating capacity
Min. heating capacity
Max. Heat Output in heating
Min. Heat Output in heating
Max. Heat Output in hot water production
Min. Heat Output in hot water production
Burner nozzles G20
Gas supply pressure G20
Max. pressure downstream of gas valve (G20)
Min. pressure downstream of gas valve (G20)
Max. gas delivery G20
Min. gas delivery G20
Burner nozzles G31
Gas supply pressure G31
Max. pressure downstream of gas valve (G31)
Min. pressure downstream of gas valve (G31)
Max. gas delivery G31
Min. gas delivery G31
Efficiency class Directive 92/42 EEC
NOx emission class
Max. working pressure in heating
Min. working pressure in heating
Max. heating temperature
Heating water content
Heating expansion tank capacity
Heating expansion tank prefilling pressure
Max. working pressure in hot water production
Min. working pressure in hot water production
Hot water content
DHW flowrate Dt 25°C
DHW flowrate Dt 30°C
Protection rating
Power supply voltage
Electrical power input
Electrical power input in hot water production
Empty weight
Type of unit
PIN CE
84
NINFA N LOW NOX 24 MCS
Unit
no.x Ø
no.x Ø
cod. 3540R880 - 01/2009 (Rev. 00)
Value
kW
25.8
kW
10.0
kW
24.0
kW
9.2
kW
24.0
kW
9.2
18 x 1.00
mbar
20
mbar
14.0
mbar
2.5
3
2.73
m
/h
3
1.06
m
/h
18 x 0.62
mbar
37
mbar
35.0
mbar
5.8
kg/h
2.00
kg/h
0.78
-
-
5 (<70 mg/kWh)
bar
3
bar
0.8
°C
90
litres
1.2
litres
8
bar
1
bar
9
bar
0.25
litres
0.2
l/min
13.7
l/min
11.4
IP
X5D
V/Hz
230V/50Hz
W
110
W
110
kg
36
C12-C22-C32-C42-C52-
C62-C72-C82-B22
0461BR0844
(Q)
(Q)
(P)
(P)
(NOx)
(PMS)
(tmax)
(PMW)
(D)