1. ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure complete and rapid draining.
1. Remove the oil dipstick and drain plug to drain the oil.
2.Reinstall the drain plug, then tighten the plug securely.
3. Refill oil and check the oil level.
Oil capacity: WX2200-WX3200: 0.6L;
WX5000-WX6200-WX6250-WX7000: 1L
Refer to the oil security card.
Dispose of the oil according to the local requirements
2. AIR CLEANER SERVICE
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction,
service the air cleaner regularly. Service more frequently when operating the generator in
extremely dusty areas.
Using gasoline or flammable solvent to clean the filter element can cause a fire or
explosion. Use only soapy water or non flammable solvent.
Never run the generator without the air cleaner. If not, rapid engine wear will result.
1. Open the air cleaner clip and open the air cover. Check the air cleaner element for
any damage and clean.
2. If the air cleaner element is dirty, please clean the air cleaner element: Wash the
air cleaner element in a solution of household detergent and warm water, then rinse
thoroughly or wash in non flammable or high flash point solvent: Pour a few drops
of engine oil, on the oil filter element then squeeze out.