CUISSON SV-31 • SV-41
Once the appliance has completed the maximum limit of 20,000 cycles, on start-up and at the end of every work cycle, the
words "ALL and OIL" flash alternately on the display to indicate that it is time to change the pump oil. Proceed with the oil
change as indicated in the section "CHANGING THE PUMP OIL" . The number of cycles already completed can be called up on
the display by pressing in sequence the
e.g. the figure "048" indicates that 48×100 = 4800 work cycles have been completed. To reset the value, once you have
pressed in sequence the
6.2
OPERATION AND PROGRAMMING
Caution: the appliance is supplied with 3 basic programmes set by the manufacturer. The user must set the remaining
programmes to meet his own personal operating requirements, depending on the type and quantity of product to be packed.
PROGRAMMING THE VAC, GAS, SEAL AND DATE FUNCTIONS
1
SWITCHING ON
Turn the ON/OFF main switch on the front of the machine to ON; the display shows the initials of the available options
for three seconds; then the programme number is displayed by the first digit to the left.
2
PROGRAM SELECTION
Select the programme (from 0 to 9) using the arrows
the functions light up.
3
SELECTING THE VAC FUNCTION (See pag.41)
Enter the program by pressing
starts flashing. Set the required value using arrows
programming by pressing the key for the required function. To obtain maximum vacuum set the
4
PROGRAMMING THE VAC+ FUNCTION (See pag.41)
Select the
function; the relative LED starts flashing. Set the required value using arrows
by pressing
, or proceed with the programming by pressing the required function key.
5
PROGRAMMING THE GAS FUNCTION (See pag.41)
Select the
function; the relative LED starts flashing. Set the required value using arrows
by pressing
, or proceed with the programming by pressing the required function key.
6
PROGRAMMING THE SEAL FUNCTION (See pag.41)
Select the
function; the relative LED starts flashing. Set the required value using arrows
by pressing
, or proceed with the programming by pressing the required function key.
7
PROGRAMMING THE DATE FUNCTION (DATER) (See pag.41)
Select the
function; the relative LED starts flashing. Set the required value using arrows
by pressing
.
It is now possible to proceed with setting other programs or proceed with the packaging.
• press
or:
• wait for approx.10 seconds and the programme is automatically saved in the memory.
REV. 01 - Cod.: 1500288
OIL CHANGE ALARM AND WORK CYCLES DISPLAY
and
keys. The figure which appears must be multiplied by one hundred,
and
keys, press the two
: the digits on the display start flashing. Select the
keys simultaneously.
. Scrolling through the programmes, the LEDs indicating
function: the VAC function LED
and confirm by means of
45
USING THE APPLIANCE
230V
, or proceed with the
value to "99".
and confirm
and confirm
and confirm
and confirm
Operation and maintenance manual / Ed. 11 - 2008
EN
400V
110V
EN