5 OPERATION
DIP switch settings
The DIP switches are located on the Digital Display PCB inside the MobileFeed.
NOTE!
To locate the Digital Display PCB, it is necessary to remove the cover that
protects the electronic parts of the MobileFeed.
Check the setting of the DIP switches on the Digital Display PCB. These switches can be set
for the display to show the wire feed speed in in/min or in m/min.
The setting (1) for the display is in/min. The setting (2) for the display is m/min.
5.3
Operating procedures
5.3.1
Operating safety precautions
Comply with all ventilation, fire, and other safety requirements for arc welding as established
in the section "SAFETY PRECAUTIONS."
1. Because of the radiant energy of the welding arc and the possibility of drawing an arc
before the helmet is lowered over the face, the operator should wear flash goggles with
filter lenses under his helmet. The helmet filter plate should be shade number 11
(nonferrous) or 12 (ferrous). All those viewing the arc should use helmets with filter
plates, as well as flash goggles. Nearby personnel should wear flash goggles.
2. The radiant energy of the arc can decompose chlorinated solvent vapors, such as
trichloroethane and perchlorethylene, to form phosgene, even when these vapors are
present in low concentrations. DO NOT weld where chlorinated solvents are present in
atmospheres in or around the arc.
3. DO NOT touch the electrode, contact tip, or metal parts when power is ON: all are
electrically energized (HOT) and can cause a possibly fatal shock. DO NOT allow
electrode to touch grounded metal. It will create an arc flash that can injure eyes. It may
also start a fire or cause other damage.
0558 012 084
- 21 -
© ESAB AB 2015