P/N 10096015
STEP 1:
Remove housing access door, nozzle screw and housing
seal.
STEP 4:
Remove web anchor bolt using 1/4 inch hex wrench. Use 3/8
inch square drive to help hold drum in place if required.
Page 2
User Instructions MSA WORKMAN PFL for Field Line Replacement
STEP 2:
Extract entire line length and remove the nozzle insert from
the housing.
While maintaining tension on the line, insert a 3/8 inch square
drive through the housing hole beneath the labels.
Turn counterclockwise until webbing slot inside the housing is
visible and aligns with nozzle opening.
STEP 5:
Remove line.
STEP 3:
Adjust so interior hole is aligned with small hole in housing
and insert line replacement housing access door to lock drum
into position.
Secure housing access door with original screw.
STEP 6:
Your Workman PFL will have one of two types of housing.
Determine which type you have by comparing your PFL with
those shown below.
For 'Type A' go to STEP 6A.
For 'Type B' go to STEP 6B.
TYPE 'A'
TYPE 'B'
© 2010 MSA