Operating instructions
8.1
Cleaning intervals
The specified cleaning intervals are recommendations from the manu-
facturer. You can clean the unit at any time if necessary. Observe the
operator's hygiene concept.
Area
Process
Condensation col-
Empty and clean
lector, floor pan
Evaporator
Clean
Recirculated air
Clean and disinfect
duct, floor pan, air
if necessary
baffles, siphon
Interior
Clean
Outer housing
Clean
Refrigeration unit,
Remove dust
condenser
8.2
Permissible cleaning types
CAUTION
Spreading water
Wet and dripping transport trolleys distribute water on paths. There is
a severe risk of slipping on wet paths.
−
Dry the transport trolley after cleaning.
−
Remove the water from the interior, e.g. by tilting the trolleys 5°.
NOTICE
Deformation at high temperatures
The polymers used deform at high temperatures and longer contact
times.
−
Restrict the contact time to max. 3 seconds.
−
Restrict the temperature to max. 120°C.
NOTICE
Bearing damage
The wheel bearings are greased. Washing out the bearing grease will
result in bearing damage.
−
Do not aim jets directly at the wheel bearings.
CoolMultiMobil
Interval
■
After each use
■
At least 1× per day
■
Weekly
■
Weekly
■
As required
■
According to the in-house
hygiene concept
■
After each use
■
In case of contamination
■
As required
■
According to the in-house
hygiene concept
■
Every six months
26 / 39