Descargar Imprimir esta página

Zoeller M267 Manual Del Usuario página 12

Publicidad

L1
L2
WHITE
GREEN
BLACK
BLACK
WHITE
RUN
CAPACITOR
FLOAT
SWITCH
BLUE
RED
(1)
(2)
BLUE
RED
(WHITE)
(BROWN)
MOTOR
START
RUN
011835
WIRING DIAGRAM FOR MODELS
WD - 230V, 1 Ph, 60 Hz.
WH - 200/208V, 1 Ph, 60 Hz.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps
are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES
REMOVE THE GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong grounded receptacle. If the installation does not have such
a receptacle, it must be changed to the proper type, wired and grounded in accordance with the National Electrical Code and all applicable local codes
and ordinances.
"Risk of electrical shock" Do not remove power supply cord and strain relief or connect conduit directly to the pump.
Installation and checking of electrical circuits and hardware should be performed by a qualified licensed electrician.
Units supplied without a plug (single and three phase) and single phase nonautomatic units with a 20 amp plug must have a motor control
and liquid level control provided at time of installation. The control device should have suitable voltage, ampere, frequency, grounding and horsepower
rating for the pump to which it is connected.
FOR YOUR PROTECTION, ALWAYS
DISCONNECT PUMP FROM ITS POWER SOURCE
BEFORE HANDLING.
To automatically operate a nonautomatic three phase pump, a
control panel is required. Follow the instructions provided with the
panel to wire the system. For automatic three phase pumps see
automatic 3 phase wiring diagram located to the far right.
Before installing a pump, check the pump rotation to ensure that
wiring has been connected properly to power source, and that
the green lead of power cord (See wiring diagram), is connected
to a valid ground. Momentarily energize the pump, observing the
directions of kick back due to starting torque. Rotation is correct if
kick back is in the opposite direction of rotation arrow on the pump
casing. If rotation is not correct, switching of any two power leads
other than ground, should provide the proper rotation.
All three phase pumps require motor starting devices with motor
overload protection. See FM0486 for duplex installations. Pumps
must be installed in accordance with the National Electrical Code
and all applicable local codes and ordinances. Pumps are not to
be installed in locations classified as hazardous in accordance
with National Electrical Code, ANSI/NFPA 70.
IMPORTANT NOTICE: Some insurance policies, both commercial and residential, extend coverage for damages incurred by product failure. You will need to
have possession of the product to support your claim in most cases. Zoeller Pump Co. will exchange the unit or refund the original purchase price once the claim
is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.
WD & WH MODEL INSTALLATION
Determining Pumping Range
in Inches (1 inch - 2.5 cm)
Tether Length
Pumping Range 9 13.5 18 22 24
Use only as a guide. Due to weight of
cable, pumping range above horizontal
is not equal to pumping range below
horizontal. Ranges are based on testing in
nonturbulent conditions. Range may vary
(3)
due to water temperature and cord shape.
YELLOW
(BLACK)
As tether length increases, so does the
variance of the pumping range.
O.L.
Models WD & WH are fully automatic. A float switch is included and
factory wired in the pump circuit to provide automatic operation
once the float switch is secured properly to the outlet pipe. Use the
diagram above to secure the float switch properly and obtain the
proper tether to customize the on-off cycle to each application.
SINGLE PHASE WIRING INSTRUCTIONS
THREE PHASE WIRING INSTRUCTIONS
L1
© Copyright 2011 Zoeller Co. All rights reserved.
5 10 15 20 22
max.
min.
NONAUTOMATIC
3 PHASE
L2
L3
GREY
BROWN
GREEN/YELLOW
BLACK
(1)
(2)
(3)
BLUE
RED
YELLOW
MOTOR
006848
4
5" MIN.
22" MAX.
SK305
20 AMP SWITCH (WD & WH MODELS)
Note: Failure to keep within proper tether limits
may prevent reliable switch operation.
Note: Cable must be mounted in horizontal
position.
AUTOMATIC
3 PHASE
013071

Publicidad

loading

Este manual también es adecuado para:

D267N267E267Wm267