Subsurface
!
Attention
The appliance is very heavy.
Model with dispenser
The floor of the installation location must not give way;
if required, reinforce floor.
To ensure that the doors can open all the way,
observe lateral minimum distances when installing the
appliance in a corner or recess (see chapter
"Installation dimensions").
If the depth of the adjacent kitchen equipment is more
than 60 cm, observe lateral minimum distances in
order to utilise the full door opening angle (see
chapter "Door opening angle").
Observe ambient temperature and
ventilation
Ambient temperature
The climatic class can be found on the rating plate. It
states the room temperature within which the
appliance can be operated.
Climatic class
Permitted ambient temperature
SN
+10 °C to 32 °C
N
+16 °C to 32 °C
ST
+16 °C to 38 °C
T
+16 °C to 43 °C
Note!
The appliance is fully functional within the room
temperature limits of the indicated climatic class.
If an appliance of climatic class SN is operated at
colder room temperatures, the appliance will not be
damaged up to a temperature of +5 °C.
143 kg
Ventilation
The air on the rear panel of the appliance heats up.
Conduction of the heated air must not be obstructed.
Otherwise, the refrigeration unit must work harder.
This increases power consumption. Therefore: Never
cover or block the ventilation openings!
Place the enclosed spacers in the designated holders
on the back of the appliance. This ensures that there
is a minimum distance between the appliance and the
wall.