Troubleshooting

Fault
Unit not cooling
Unit not heating
Unit underperforming
or failing in cooling /
heating mode
Moisture on the un-
derside of the air
distributor
Water dripping out of
air distributor
Remote control not
working
Unit not responding
to remote control
commands
Should these actions not resolve the corresponding
problem, please contact Truma Service.
18
Cause / Action
Thawing process in progress
The temperature set on the re-
mote control has been reached
or is too high
Thawing process in progress
(outside temperature between
4 °C and 7 °C)
Outside temperature below 4 °C
Filter soiled, replace filter
Air ways to the outside soiled /
blocked
Close windows and doors and
set the fan level to high
Condensation trap on external
unit blocked
No proper seal between unit
and roof (e.g. faulty seal)
Angle of tilt of system too great
Check remote control batteries
and replace if necessary
Check for obstructions between
remote control and IR receiver

Technical data

Power supply
230 V – 240 V ~, 50 Hz
Current consumption
Cooling: 4.2 A
Heating: 3.7 A
Start-up current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Volumetric air flow
Max. 400 m³/h
Operational limits
+4 °C to 40 °C
Maximum tilt during operation
8 %
Weight
33.5 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
See type plate on unit
Installation dimensions
1008
195
(215)
530
(dimensions in mm)
670
400
(380)