Installing Filters; 230 V Electrical Connection; Function Test / Mounting For The Remote Control - Truma Aventa comfort Instrucciones De Uso

Ocultar thumbs Ver también para Aventa comfort:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
Covering tape, which is available as an accessory, can be
used to cover gaps between the air distributor and the
roof.

Installing filters

Insert the filters in the panels and connect them to the air
distributor.

230 V electrical connection

The 230 V electrical connection must always be made
by an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721, for example, in Germany). The information
given here is not intended as instructions for you to carry out.
It is for assisting the expert assigned to carry out the job, act-
ing as auxiliary information when connecting the appliance!
Connect the power supply cable that has been routed to the
connecting point.
All cables must be secured with clamps!
For maintenance or repair work, an isolating device must be
provided on the vehicle side to provide all-pole isolation from
the mains, with a contact interval of at least 3.5 mm.
Function test /
Mounting for the remote control
Install the mounting for the remote control in the required
location.
All device functions must then be tested as described in
the operating instructions.
Once the unit has been installed, the person completing the
installation must check that the condensation traps are not
obstructed.
The operating instructions must be handed to the owner of
the vehicle.
23

Publicidad

Tabla de contenido
loading

Tabla de contenido