Clearance around the air conditioning system

The clearance around the outer unit must be 20 mm at the
front and 100 mm at the sides. Clearance of 30 mm must
be maintained at the rear. Truma recommends clearance of
200 mm so that the exhaust air can be freely expelled.
The clearance around the air distributor must ensure that air
can escape unrestricted. There must be a clearance of at least
40 mm to the side. The swivel range of flaps and doors must
be taken into account.

Air inlets / Air outlets

Condensation traps

The condensation is led away over the roof of the vehicle.
The right to effect technical modifications is reserved!

Declaration of conformity

1. Information about the manufacturer
Name:
Truma Gerätetechnik GmbH & Co. KG
Address: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn
2. Device identification
Type / Model:
Aventa comfort air conditioning unit
3. Meets the requirements of the following EC Directives
3.1 Electromagnetic Compatibility 2004/108/EC
3.2 Low Voltage Directive 2006/95/EC
3.3 Radio Interference in Vehicles 72/245/EEC
(with the supplements)
3.4 End-Of-Life Vehicle Directive 2000/53/EC
and bears type approval numbers E24 10R-030696 and
the CE symbol.
4. Basis of the conformity assessment
EN55014-1; EN61000-3-2; EN61000-3-3; EN62233;
EN55014-2; IEC / EN60335-1; IEC / EN60335-2-40;
2009/19/EC; DIN EN378-2
5. Information and the function of the signatory
Signature: Dr. Schmoll
Managing Director / Engineering
Putzbrunn, 18/02/2011