SYMPTOM
Oil appears milky or foamy.
Oil leaking from unit.
Detergent will not siphon into Low
Pressure Detergent mode.
Water flows back into detergent
container.
Water flows from the nozzle when the
trigger gun is in the "OFF" position.
Mi-T-M CD-1002/1502-3MUH/3MUH1 Operator's Manual
TROUBLESHOOTING
PROBABLE CAUSE
Water in oil.
DO NOT USE!!!!!
Detergent strainer is not completely
Detergent strainer is obstructed.
Detergent hose is obstructed, cut
or kinked.
Not in Low Pressure mode.
Nozzle assembly is plugged.
Too many high pressure hose
extensions attached to the water outlet.
Ball & Spring in Venturi stuck.
Ball & Spring in Venturi reversed,
missing or corroded.
Gun is malfunctioning.
ACCESSORIES
15-0006:
50-0085:
50-0086:
50-0087:
50-0090:
50-0091:
50-0092:
50-0093:
50-0094:
851-0007:
AW-7005-01WK:
AW-7900-0300:
REMEDY
Change pump oil. Fill to proper
level.
Contact Customer Service.
Check; submerge if necessary.
submerged in detergent solution
Inspect, clean or replace.
Inspect, clean or replace.
Push nozzle cover away from the gun.
Clean or replace.
Use one extension maximum.
Remove, clean or replace.
Remove, clean or replace.
Repair or replace.
3/4" Supply Hose
Extension Wand 18"
Angled Extension Wand 33.5"
Rotating Nozzle .035 mm
Wet Sandblaster
Foaming Wand
Hand Brush
Rotating Brush
Floor/Wall Brush
Extension Hose - 50'
Wheel Kit
Hose Reel
19