Descargar Imprimir esta página

Scheppach Compact 15t Traduccion Del Manual De Instrucciones Originale página 50

Ocultar thumbs Ver también para Compact 15t:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
15. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Use a portable safety switch (PRCD) if the residual
current protective circuit (RCD) in the mains power
supply is not provided with a rated residual current
of no more than 30 mA.
The mains power connection is protected with a 16
A slow-blow fuse.
Damaged electrical connection cables
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the designation H07RN-F.
The printing of the type designation on the connection
cable is mandatory.
• The product fulfils the requirements of
EN 61000-3-11 and is subject to special connection
requirements. This means that use at any freely se-
lectable connection points is not permitted.
• The device can cause temporary voltage fluctua-
tions in unfavourable mains conditions.
50 | GB
• The product is intended exclusively for use at con-
nection points which
a) do not exceed a maximum permitted mains im-
pedance "Z"
(Zmax = 0.330 Ω (400 V)), or
b) have a continuous current carrying capacity of the
mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Three-phase motor 400 V 3~ / 50 Hz
Mains voltage 400 V 3N~ / 50 Hz
Mains power connection and extension leads must be
5-core = 3~ + N + PE.
• Extension cables must have a minimum cross sec-
tion of 1.5 mm² (≤ 25m).
• Extension cables must have a minimum cross sec-
tion of 2.5 mm² (> 25m).
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
16. Disposal and recycling
Notes for packaging
Notes on the electrical and electronic equipment
act [ElektroG]
Electrical and electronic appliances do not
belong in household waste, but should be
collected and disposed of separately.
• Used batteries or rechargeable batteries that are not
installed permanently in the old appliance must be
removed non-destructively before disposal. Their
disposal is regulated by the battery act.
www.scheppach.com
The packaging materials are recy-
clable. Please dispose of packag-
ing in an environmentally friendly
manner.

Publicidad

loading

Este manual también es adecuado para:

59054229969