Electrical Connection; Disposal And Recycling - Scheppach Compact 8t Traducción Del Manual De Instrucciones Original

Ocultar thumbs Ver también para Compact 8t:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 104

14. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
• The product fulfils the requirements of
EN 61000-3-11 and may only be used at the follow-
ing connection points: This means that use of the
product at any freely selectable connection points
is not allowed.
• Given unfavourable conditions in the power supply the
product can cause the voltage to fluctuate temporarily.
• The product is intended exclusively for use at con-
nection points which
a) do not exceed a maximum permitted mains
impedance "Z"
(Zmax = 0.382 Ω), or
b) have a continuous current carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F. The printing of the
type designation on the connection cable is mandatory.
The mains power connection must be protected with a
max. 16 A slow-blow fuse.
Three-phase motor 400 V / 50 Hz (Fig. 17)
Mains voltage 400 V / 50 Hz.
Mains power connection and extension leads must be
5-core = 3 P + N + SL. - (3/N/PE).
AC motor 230V / 50Hz
Mains voltage 230V / 50Hz
Extension cables must have a minimum cross section
of 1.5 mm².
When connecting to the mains or in the event of the
machine being moved to another location, the turning
direction must be checked. It may be necessary to
change the polarity.
Rotate the pole-changing device (400V) in the unit
plug. (Fig. 17)
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Data of machine type plate
• Motor data - type plate

15. Disposal and recycling

plastics. Take defective components to special waste
disposal sites. Check with your specialist dealer or mu-
nicipal administration!
www.scheppach.com
The device is supplied in packaging to avoid
transport damages. This packaging is raw
material and can thus be used again or can
be reintegrated into the raw material cycle.
The device and its accessories are made
of different materials, such as metals and
GB | 47

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Compact 10t5905419901590541990259054239015905423902

Tabla de contenido