Descargar Imprimir esta página

Vaillant sensoHOME VRT 380f/2 Manual De Uso E Instalación página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
The installation assistant switches
to the System control reception
strength function.
Condition: Wireless outdoor temperature sensor
available
If a wireless outdoor temperature
sensor is available, this must be paired.
To do this, follow all of the installation
instructions in its instructions.
To pair the wireless outdoor temper-
ature sensor, press the button on the
radio receiver unit. The LED flashes
green.
Activate the outdoor temperature
sensor as described in its instructions.
The LED on the radio receiver unit
flashes briefly. Once the pairing process
is complete, the LED no longer lights
up.
Go to the chosen installation site for the
wireless outdoor temperature sensor.
If the reception strength at the chosen
installation site is < 4, find a new in-
stallation site for the outdoor temper-
ature sensor – one that has a reception
strength of ≥ 4.
Install the outdoor temperature sensor
at the installation site.
Determining the control's installa-
tion site in the building
9.
Choose an installation site that meets
the following requirements.
– Internal wall of the main living room
– Installation height: 1.3 ... 1.5 m
– Not in direct sunlight
– Not affected by heat sources
Determining the reception strength
of the control at the chosen install-
ation site
10. Go to the chosen installation site for
the control.
11. Close all doors behind you on the way
to the installation site.
12. Press the wake-up/sleep button on
the upper side of the unit if the display
is off.
18
Condition: The display is on, The display shows
Radio communication interrupted
Make sure that the power supply is
switched on.
Condition: The display is on, System control recep-
tion strength < 4
Find an installation site for the control
that is within the reception range.
Condition: The display is on, System control recep-
tion strength ≥ 4
Mark the position on the wall where the
reception strength is sufficiently high.
Attaching the unit mounting
bracket to the wall
B
A
13. Remove the unit mounting bracket
from the control as shown in the fig-
ure.
B
C
14. Secure the unit mounting bracket in
accordance with the figure.
Operating and installation instructions 0020323648_01
Ø 6
A

Publicidad

loading

Este manual también es adecuado para:

Vrt 380f/2