The minimum current necessary to operate the control-box is 1,5 µA (DLG 976), 3µA (LME11/21). When
the measurement of the current is required it is necessary to disconnect the lead to the probe and insert in its
place a microammeter for direct current (see fig. under).
Microammeter full-scale 50 µA
SATRONIC DLG 976 CONTROL INFORMATION SYSTEM
The SATRONIC DLG 976 control is a micro-processor control which provides information about the cur-
rent operation of the burner and the cause of any faults. The information is available by reading the "flash
code" at the red LED within the lockout reset button as detailed below. By the use of additional monitoring
equipment a short history of recorded faults is also available. There are two types of additional monitoring
devices available from Satronic Ltd. The "satropen" is a small pocket reader designed to give a visual read out
of status, flame current and supply voltage. Computer software is available to allow access to the current
information and stored data.
On burner failure the red LED is permanently illuminated for a period of approximately 10 seconds, fol-
lowed by a brief "dark phase", then one of the following flash codes will indicate the cause of the fault. This
indication will repeate as long as the lockout reset button is not reset.
Message
waiting for air proving
switch
pre-purge (tv1)
pre-ignition (tvz)
safety time (ts)
delay 2nd stage (tv2)
running
low mains voltage
Flash-Code Key
short pulse
long pulse
short pause
.
long pause
_
Connection diagram and control sequence of LME11...
K1
K2/1
K2/2
R / W
T
GP
AL
M
Z
STB
H
Si
N

IONIZATION CURRENT

SATRONIC DLG 976
min. 1,5 µA
1
FAULT DISPLAY MESSAGES
Flash-Code
Error diagnosis
❘ ❘.
Error message
lockout
❘ ❘ ❘ .
safety time
❘ ❘ ❘ ❘.
stray light
❙ ❘.
❙ ❘ ❘ .
air proving switch
❘ _
in closed position
❘ ❙ ❙ _
air proving switch
time-out
air proving switch
opened
loss of flame
Flash-Code for manual lock out
manual/external
lock out
CONTROL BOXES LME11
RESET
K3
p
V1
EK2
7101a24e/0609
420010749000 Azur 30/40/60/80 Blu 120 P
Flash-Code
❘ ❙ ❙ ❙ ❙
❘ ❘ ❙ ❙ ❙
❙ ❙ ❘ ❘ ❘
❘ ❘ ❘ ❙ ❙
❘ ❘ ❘ ❘ ❙
❙ ❙ ❙ ❙ ❘
❘ ❘ ❙ ❙ ❙ _ ❙ ❙ ❙ ❙ ❙
A
B
SB / R
W / GP
AL
M
Z
V1
LP
FS
EK2
t1
tw
t10
t3
pag.7
1
min. 3 μA
Siemens
LME11/LME21-22
Possible fault
within lock out safety time
no flame establishment
stray light
during monitored phase,
detector may be faulty
air proving switch
contact welded
air proving switch does not
close within specified time
air proving switch opens
during start or operation
loss of flame during operation
C
D
t4
t3n
TSA
EN