Loading capacity of the floor
Check the load-bearing capacity of the floor, referring to the weight of the product given in
the paragraph "TECHNICAL DATA". If the floor does not have a suitable load-bearing
capacity, adequate countermeasures must be taken.
Minimum safety distances
Install the product incompliance with there commended safety distances from heat sensitive
or inflammable materials and not inflammable, from load bearing and other walls and also
from wooden elements, furniture, etc.
The minimum distances are:
- 4" (10 cm) from the wall behind the stove;
- 6" (15 cm) from the side wall;
- 32" (80 cm) in the heat radiation area and from the hot air fan outlet.
In the case of flooring that is heat sensitive or inflammable the floor must be protected with
non-combustible insulating material, e.g. sheets of steel plate, marble, tiles, etc.
The floor protection must extend:
- under the product;
- a minimum of 6" (152 mm) in front of unit and beyond each side of the fuel loading and ash
removal opening (4" / 10cm from the external side of the coating).
Connection to the flue must respect minimum safety distances from heat-sensitive structural
components or inflammable materials (wood paneling, beams or ceilings, etc) shown in
figures.
Warning!
The stove will become hot while in operation. Keep children away from all stove surfaces.
Direct contact with stove while operating may cause skin burns.
Keep any combustible product such as wooden furniture, curtains, carpets, combustible
liquids, etc. well away from the stove when it is lit (minimum distance 32"/ 80 cm).
It is recommended that greater distances than those indicated above be left all round the
stove to make any necessary work on the appliance easier.
Install vent at clearances specified by the vent manufacturer.
Certain local code restrictions may apply.
Check with Local Officials first before installing.