Descargar Imprimir esta página

Beninca CP.ZED230-E Manual Del Usuario página 11

Ocultar thumbs Ver también para CP.ZED230-E:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Power supply
3-4
Flashing light
4-5
Motor light
6-7-8
Motor 1/2
9
COM
10
SWO
11
SWC
12
STOP
13
PHOT
14
OPEN
15
CLOSE
16
Step-by-Step
17-18
24 Vac
19-20
AUX
21-22
COSTA
23-24
Aerial
CM-CM
Capacitor
0-12-12
Secondary
L1-N1-T
Primary
J3
Radio receiver
Should two motors be used, connect the limit switches of one single motor to the control unit.
The connection between CP.ZED230-E and the ZED.SC card is shown in Fig.3.
F1
Motor protection fuse
F2
Output protection fuse of accessories and signals
1)
Power the control unit
2)
Manually unlock and completely close the door.
3)
Adjust the closing limit switch cam, the SWC display segment switches on. If the SWO segment switches on, invert
the SWO<>SWC limit switch wires.
4)
Move the door into the desired open position. Provide for some overrun centimetre.
5)
Adjust the opening limit switch cam. The SWO display segment switches on.
6)
Lock the door again.
9)
Start the autoset operation by entering the AUTO menu in the LCD display (see "PROGRAMMING" and "AUTO"
menu).
10) The door must move in the closing phase. If this does not occur, the activation wires (6<>8) must be inverted. Move
the door leaf back to the completely open position. At completion of the closing operation, the display shows the
wording "OK" to confirm the complete learning of the stroke.
CP.ZED230-E CONTROL UNIT
WIRE DIAGRAM
Description
Input, 230VAC 50Hz (1-Phase/2-Neutral)
Connection of flashing light, 230Vac 40W max.
Connection to the courtesy light (230VAC 40+40W max.).
Connection to motor 1/2 : (6-speed/7-Com/8-speed)*
Should 2 motors be used, connect the second motor in parallel.
Common for limit switch and all control inputs.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, STOP push button (N.C. contact)
Input, connection to safety devices, N.C. contact
(e.g. Photocells)
Input, OPEN push button (N.O. contact)
Input, CLOSE push button (N.O. contact)
Input, step-by-step push button (N.O. contact)
Output, power supply of accessories, 24Vac/1A max.
Normally Open (N.O.), clean contact, not powered, configurable as
SCA/II°CH/PHOTO TEST.
Input, safety edge contact
Resistive edge: Closed "DAS" jumper
Mechanical edge: Open "DAS" jumper
If the safety edge is activated in the opening phase, the gate stops.
In the closing phase, the gate stops and the performs a movement reversion
(opens) for 3s.
Connection to the radio receiver card of the aerial (23-screen/24-signal).
Connection, capacitor
Connection, winding of secondary transformer
Connection, winding of primary transformer
Built-in radio receiver
IMPORTANT:
FUSES
LIMIT SWITCH ADJUSTMENT
11

Publicidad

loading