The activation time of the service light is adjusted.
With parameter :0, the area light function is activated. The light is
TLS
switched on when the motor is moving and during the TCA dwell time.
The light switches off when the motor stops.
The triggering threshold of the anti-crash device (Encoder) during the
normal speed phase.*
SEAV
99: maximum sensitivity - 0: minimum sensitivity
The triggering threshold of the anti-crash device (Encoder) during brak-
ing.*
SEAR
99: maximum sensitivity - 0: minimum sensitivity
The operating mode of the auxiliary output to terminals 19/20 is preset.
See wire connections in figure 2.
0: output configurated as SCA (open gate indicator light): Off with closed
door, on with open door, slow flash during opening, rapid flash during
AUX
closing.
1: output configurated as radio channel II integrated receiver.
2: output configurated as PHOT TEST (photocell test).
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse
IbL
of the transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before
PRE
the starting of the motor.
Off: disabled forewarning flashing light.
The lock function in the closing phase is enabled or disabled.
On: Lock function is enabled.
blc
After the closing limit switch activation, the control unit delays the stop of around
1 sec, so as to allow a better stop of the door leaf against the stoppers.
Off: Lock function is disabled.
During the TCA time, the blinker is enabled or disabled.
ltca
On: Activated blinker.
Off: De-activated blinker.
The pick-up function with ENC:OFF logics is activated or deactivated.
On: the function is enabled. The first two seconds of operation are carried out
spn
at maximum torque.
With ENC:ON logics, pick-up is automatically adjusted by the control unit.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic/semiautomatic operation.
During the TCA phase, the PP and PED controls are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled.
On: Enabled encoder.
Off: Disabled encoder (to be used with ZED series motors that are not equipped
ENC
with built-in Encoder).
NB: The Encoder can be possibly reset (from OFF to ON). A new self-calibration
procedure is required (AUTO menu).
FUNCTION
FUNCTION
MEMO
MIN-MAX-(Default)
0-240-(60s)
0-99-(0%)
0-99-(0%)
0-2-(0)
MEMO
DEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)