Descargar Imprimir esta página

Beninca CP.ZED230-E Manual Del Usuario página 15

Ocultar thumbs Ver también para CP.ZED230-E:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s
- activate pre-blinking
Perform the operations described below step by step:
Step
Press
Display
1
2
3
4
5
6
7
8
9
10
11
12
13
In the event of malfunctions, by pressing key + or - the status of all inputs (limit
switches, control and safety) can be displayed. One segment of the display is
linked to each input. In the event of failure it switches on according to the follow-
ing scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represent-
ed by the horizontal segments.
The control unit checks the correct operation of the safety devices. In the event of failure, the following messages may
be displayed:
Error, self-learning stroke:
ERR
- activation of any input by the user
- door leaf i the closing limit switch
- HTR:ON logics
- memorisation of remote controls
Check of management circuit integrity has failed
ERR1
Error, PHOTO TEST
ERR2
Encoder is broken.
ERR3
EXAMPLE OF PROGRAMMING
First menu
PAR
First function of the first menu
TCA
Value currently set for the function selected
040
Set the desired value with the <+> and <-> keys
100
The value is programmed
PRG
When programming has been made, the display goes to the function just set
TCA
Press <+> and <-> simultaneously to go to the higher menu
PAR
Second menu
Log
First function of the second menu
TCA
Press <-> several times to select PRE logic
Pre
Value currently set for the function selected
OFF
Set the desired value with the <+> and <-> keys
ON
The value is programmed
PRG
When programming has been made, the display goes to the function just set
Pre
Press <+> and <-> simultaneously to go to the higher menu and quit programming or
PAR
wait 30s.
DIAGNOSTICS
ERROR MESSAGES
Notes
���
����
����
���
���� �����
����
���
15

Publicidad

loading