Descargar Imprimir esta página

Beninca CP.ZED230-E Manual Del Usuario página 14

Ocultar thumbs Ver también para CP.ZED230-E:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
MENU
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
The operating mode of the PHOT input is selected.
On: PHOT input is activated in both opening and closing.
In the opening phase: when the contact is opened, the motor stops. When the
photocell is released, the motor restarts with an opening movement.
PHTo
In the closing phase: when the contact is opened, the motor stops. When the
photocell is released, the motor inverts its movement direction (opens).
Off: PHOT input is activated only in the closing phase.
In the closing phase: when the contact is opened, the motor stops and the
movement direction is immediately reversed (opens).
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-
by-step function.
PP
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
With AUX:1 parameter, the radio channel II function to terminals 19/20 is activated.
With AUX:0 e AUX:2 parameter, the service light is activated according to the time preset by TLS
parameter.
2Ch
By selecting this function, the receiver awaits (Push) the pressure of the key to be matched with that
function.
If the code is valid, the same is memorised and the OK message is displayed.
If the code is not valid, the Err message is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
CLR
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
RTR
Completely erase the receiver memory. Confirmation of operation is required.
MENU
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is
NMAN
pressed once more, the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
RESET of the control unit. WARNING: This resets the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button
RES
<PG> is pressed once more, the control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the
receiver.
auto
See the Self-adjustment of operating parameters section
OPERATING MODE WITH ENABLED/DISABLED ENCODER
With ENC=ON LOGICS:
- the anti-crash sensor is activated. The sensitivity must be adjusted through the SEAV and SEAR parameters according
to regulations in force.
Once the stroke length is stored in memory by the control unit, the latter will automatically manage the braking phases
during opening and closing. The braking space can be increased or decreased by the TSM parameter. The stroke is
constantly updated and stored in memory together with the gate position in the event of power failure.
With the ENC=OFF LOGICA (To be used with motors without encoder):
- the anti-crash sensor is deactivated.
- if the parameter TSM>0 (braking activated), the control unit starts the braking phase after triggering the limit switch.
Duration is preset through the parameter itself.
NB: Preset the TM parameter for a value higher than the stroke time.
14
FUNCTION
FUNCTION
FUNCTION
MEMO
DEFAULT
(OFF)
(OFF)

Publicidad