Configuring the Direct Panel

The street panel´s parameters can be programmed on the keypad.
For this you must enter in configuration mode via a programming access code after
pressing 'A'.
Programming Access code: A + 4444 (default code).
If the code is correct, a confirmation tone sounds (beep-beep).
The parameters that can be configured are:
Position
Adjustments
Parameter
Activation time
01
lock-Releases
Exit button
02
activation time
Panel type
03
04
Block number
05
Sub-Block num.
06
Panel number
07
Door Sensor Time
Opening code
08
09
Programming
Code
10
MASTER panel
11
Mode
Guard Unit
12
Monitoring volume
RESETTING
13
Parameters
Camera focus
14
Pag 56
Comments
Possible Values
[
]
default
01-99''
Open-door relay activation from the phone or
[03]
access´ control.
00-99''
Activating lock-release relay from the exit button
[06]
(connected to the 'Bs' and '-' terminals).
0:
Sub-Block
[1]:
Block
Configuration of the panel type.
2:
E. General
00-99
Block number the panel belongs to.
[00]
00-99
Sub-Block number the panel belongs to.
[00]
0-9
Panel number.
[0]
000-250
Maximum time the door can be left open after
[000]
not active
the lock-release.
0000-9999
Opening code from the keypad. The opening
[AAAA]
not active
code is entered as follows:
A + XXXX (4 digits).
Programming Access code.
0000-9999
[4444]
[0]: No
Activating the panel as MASTER to program
1 : Yes
telephones.
[0]: No Reset
Reset to night mode by writing «1» in this
1 : Reset
position.
0-9
Adjust street panel monitoring volume
[5]
[0]: No Reset
Reset to the default values by writing «1» in this
1 : Reset
position.
0-9
The selection of different values 0-9, represent
[9]
each of the video screens to capture.
details on screen capture, see Camera Focus (next
page).