List of set up parameters (MIG/MAG-Pulsed MIG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the manual MIG (
gic MIG (
) process by setting the type of mate-
rial to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 1 m/min, Maximum 22 m/min, Default 1.0m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5
Part thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6
Corner bead
Lets you set bead depth in a corner joint.
7
Arc length
Allows regulation of the arc length during welding.
Minimum -5.0, Maximum +5.0, Default syn
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
11
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50%
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, Maximum +2.00, Default syn
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
20
Double pulsed
Allows enablement of the "Double Pulsed" function.
Allows regulation of the pulsation amplitude.
Minimum 0%, Maximum 100%, Default ±25%
21
Pulse frequency
Allows the impulse frequency to be regulated.
Minimum 0.1Hz, Maximum 5.0Hz, Default 2.0Hz
22
Secondary voltage
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during
the various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
25
Initial increment
Allows regulation of the wire speed value during the
first "crater-filler" welding phase.
Makes it possible to increase the energy supplied to
) or syner-
the part during the phase when the material (still cold)
requires more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
26
Crater filler
Allows regulation of the wire speed value during the weld
closing phase.
Makes it possible to reduce the energy supplied to the part
during the phase when the material is already very hot,
thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 120%
27
Initial increment time
Lets you set the initial increment time. Lets you auto-
mate the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
28
Crater filler time
Lets you set the "crater filler" time. Lets you automate
the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
30
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
202
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
330
Voltage
Lets you set welding voltage.
399
Welding speed
Lets you set welding speed.
Minimum 1cm/min, Maximum 500cm/min, Default
35cm/min (reference speed for manual welding)
401
Analog inputs
405
Analog outputs
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
Allows access to the higher set-up levels:
USER: user
SERV: service
SELCO: Selco
43