Descargar Imprimir esta página

Bosch HBL33 Manual De Instalación página 13

Ocultar thumbs Ver también para HBL33:

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connection
The four-wire connection is preferred, but where local codes permit, the three wire
connection is also acceptable.
Four-wire Connection
Junction box |
Cable from
SN
power supply
White wires
Ungrounded Neutral
i
Black wires
Bare or green wires
Cable
from oven
~ U,Ltisted conduit connector
*
Connect the red oven wire to the red electrical supply wire (hot wire).
*
Connect the black oven wire to the black electrical supply wire (hot wire).
*
Connect the white neutral oven wire to the white neutral (not bare ground)
electrical supply wire.
*
Connect the bare ground oven wire to the bare ground electrical supply wire.
Three-wire Connection
Junction box
Cable from
power supply
White wires
Black wires
Bare or green wire
Cable
from oven
U.L.-listed conduit connector
*
Connect red wire from oven to red wire injunction box.
*
Connect black wire from oven to black wire in junction box.
*
Connect both green ground wire and white wire from oven to white (or gray)
neutral wire in junction box.
The conduit cable, where connected at the oven, swivels. Rotate conduit cable
upward (or downward) and direct through hole prepared in cabinet to attach to J-
Box.
To maintain serviceability, the flex conduit must not be shortened and should be
routed to permit temporary removal of the oven.
English 11