Prepare holes at fastener
locations as identified below:
•
For walls, wall studs, or floors composed of solid wood
or metal, drill 1/8" (3mm) pilot holes.
•
For walls or floors composed of drywall, sheet-rock or
other soft materials, drill 3/16" (5mm) holes to a
minimum depth of 1¾" (45mm), then tap plastic
anchors into each of the holes using a hammer.
•
For walls or floors composed of concrete or concrete
block, drill 3/16" (5mm) holes to a minimum depth of
1¾" (45mm), then tap concrete anchors into each of
the holes using a hammer.
•
For walls or floors havinq ceramic tile coverinq, drill 3/
16" (5mm) holes through the tile only, then drill into the
material behind the tile as indicated immediately
above.
Range leg will
slide into bracket
slot after installation.
Figure 7: Anti-Tip Bracket
Cabinet
<_ \°°_"
Wall Line
_.,I
X
I-.!I From Edge
_$
of Range
/
I
I
\
Cabinet
Front edge l_lI !_I ×
of right
typical--
cabinet
!
either side
X = 4½" (114mm) [for 30" range]
X = 6¾" (171mm) [for 36" range]
X = 4½" (116mm) [for 48" range, right side]
X = 31¼"(83mm) [for 48" range, left side]
Mounting Anti-Tip Bracket
The floor mounted bracket shall be installed as follows:
,
Place bracket on floor in position shown in Figure 8.
•
30" and 36" bracket may be used in either corner of
the installation area.
2.
Secure to floor and wall stud using the (4) 1½" (38mm)
Phillips head screws provided.
3.
Later, when the unit is installed, the adjustable leg will
slide under the bracket, as shown in Figure 7.
4.
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Figure 8: Placement of Anti-Tip Bracket (Top View)
English 12