Thisappliance h asbeentested in accordance withANSI
Z21.1, S tandard f orHousehold C ooking Appliances ( USA)
andinaccordance withCAN1.1-M81 Domestic G as
Ranges (Canadian).
Thisappliance c omplies w ithoneor moreof thefollowing
standards:
UL858,Standard f ortheSafety of Household E lectric
Ranges
UL923,Standard f ortheSafety of Microwave C ooking
Appliances
UL507,Standard f ortheSafety of Electric Fans
ANSIZ21.1, A merican N ational Standard f or
Household C ooking GasAppliances
CAN/CSA-C22.2 No.113-M1984 F ansandVentilators
CAN/CSA-C22.2 No.61-M89 Household C ooking
Ranges
It istheresponsibility of theowner andtheinstaller t o
determine ifadditional requirements and/or s tandards
apply to specific installations.
2 - 1/2" wrenches
1/8"(3.17mm) drillbit
3/16"(4.76mm) drillbit
12"Adjustable w rench
Hand or electric drill
Tapemeasure
T-20Torxscrewdriver
Marking instrument
Level
Furniture dolly
Phillips &flathead
Protective g loves
screwdrivers
Items Not Included
.......
3/16" (4.76mm) Drywall /
Pipe Compound / Tape
Concrete Anchors
Rope/Twine
3/4" (19mm) Flex Line
Strain Relief
Cord Kit or Conduit
2 - NPT Flare Adapters
Step 1: Ventilation
Requirements
It is stronqlv recommended that a suitable exhaust hood be
installed above the range. Downdraft ventilation should not
be used. The table on page 4 indicates the ventilation hood
options and blower capacity guidelines that are
recommended for use with all THERMADOR ® ranges.
IMPORTANT:
Ventilation hoods and blowers are designed for use with
single wall ducting. However, some local building codes or
inspectors may require double wall ducting. Consult local
building codes and/or local agencies, before starting, to
assure that hood and duct installation will meet local
requirements.
Due to the high heat of the rangetop burners, do not install
a microwave oven/ventilator
combination above the range,
as these type of units do not provide the proper ventilation
and are not suitable for use with the range.
NOTICE:
Most range hoods contain combustible components which
must be considered when planning the installation.
,
,
,
Select Hood and Blower Models:
For wall installations, the hood width must, at a
minimum, equal the width of the range. Where space
permits, a hood larger in width than the range/rangetop
may be desirable for improved ventilation performance.
For island installations, the hood width should
overhang the width of the range by a minimum of 3"
(76mm) on each side.
Hood Placement:
For best smoke elimination, the lower edge of the hood
should be installed 30" (762mm) above the range
cooking surface (see Figure 1).
If the hood contains any combustible materials (i.e. a
wood covering), it must be installed a minimum of 36"
(914mm) above the cooking surface (see Figure 1).
Consider
Make-Up Air:
Due to the high volume of ventilation air, a source of
outside replacement air is recommended. This is
particularly important for tightly sealed and insulated
homes. A qualified heating and ventilating contractor
should be consulted.