MAINTENANCE IN CASE OF ENGINE INACTIVITY
In case of long periods of engine inactivity
(more than 6 months), carry out the
protective engine treatment. If the engine
is not used for a further period of time,
check the need to repeat the protective
treatment for other 6 months (see section
"Engine protection in case of long periods
of inactivity" on page 24).
CHECKS AFTER A LONG PERIOD OF ENGINE INACTIVITY
Before starting the engine, it is good
practice to carry out some checks.
1 - Check that there are no visible
leakages or damage to the engine
components and the relevant electric
connections.
2 - Remove and thoroughly clean any
foreign material deposits on engine
components.
3 - Check the level and status of fluids:
fuel (see page 28), DEF fluid (see page
38-40), engine oil (see page 54), coolant
(see page 64).
WASHING THE ENGINE
IMPORTANT
It is recommended to wash the engine
only in case of real need.
Washing must be carried out with
engine off and cold.
Ignition key removed, wait at least
6 minutes before disconnecting the
negative battery cable.
Before washing the engine, properly
protect its components.
Do not absolutely direct jets of water or
steam jets towards:
- Cable joints and engine wiring electrical
connectors.
English
IMPORTANT
In any case, it is advisable to start the
engine and bring it to the operating
temperature of 70°C - 80°C (158°F -
176°F) for five minutes at least on a
monthly basis.
4 - Check the integrity of air filter, belt,
rubber sleeves and relevant fixing clips
(in case of replacements, proceed as
indicated in the routine maintenance
tables).
IMPORTANT
In case of need, contact a workshop
authorised by VM MOTORI STELLANTIS
EUROPE.
- Alternator, starter motor.
- Fuel injection circuit devices.
- Electro-injectors.
- Electrical sensors installed on the engine.
- Electronic engine management control
unit.
- Engine intake air filter and related mass
flow sensor.
- Components of exhaust gas after-
treatment system ATS.
When washing is complete, remove all
protections, start the engine and leave it
running at idle until it is completely dry.
51