Descargar Imprimir esta página

Holex HCT Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 113
HOLEX HCT electronic torque wrench
de
4.2.
CONTROL PANEL
en
bg
zh
da
1 TFT display 2 Up 3 Right / Next / Acknowledge 4 Down 5 Left / Back 6 Send
fi
button
4.3.
DISPLAY
fr
1
2
3
it
hr
10
lt
9
Menu
nl
1 Battery capacity 2 Bluetooth (if Bluetooth activated) 3 Fault symbol/message
symbol (if there is a fault) 4 Direction of rotation display 5 Time 6 Current torque
7 Unit of measure 8 Peak value 9 Menu 10 "Not calibrated" lights up: Measure-
no
ment within the non-calibrated range
5.
Transport
Transport in the original packaging at temperatures between -20°C and +70°C and at
pl
a humidity below 90%, non-condensing. Prevent from falling.
6.
Initial commissioning
pt
ro
sv
sk
A
sl
CAUTION
Exploding rechargeable batteries
Risk of injury to hands and body.
es
▶ Use only the rechargeable battery supplied.
▶ In the event of damage, deformation or heat build-up, stop using the re-
chargeable battery.
▶ Only charge rechargeable batteries with the corresponding charger.
cs
1. Turn rotary catch anti-clockwise with slot-head screwdriver and remove it.
2. Remove contact fuse.
3. Insert rotary catch and turn clockwise with slot-head screwdriver.
hu
12
1
2
5
4
6
4
5
16:32
0.0
Nm
Peak
7.
Switches on
3
1
B
i
Torque wrench is tared automatically each time it is switched on.
1. Place the torque wrench on a flat surface and keep it still.
2. Press the OK button and keep it depressed for around two seconds in order to
switch on the torque wrench.
▶ "Tare - Do not move" is displayed.
CAUTION! Incorrect taring. Do not apply any loads to or move the torque
wrench during the taring process.
6
3. If the torque wrench switches to measurement mode, the taring process is com-
plete.
7
▶ The measurement mode last used is displayed.
8.
Menu navigation
8.1.
MEASUREMENT MODES
8
i
Switch from main screen to Measurement method.
0.0
Nm
Menu
8.1.1.
Torque
Menu
1. If a password is required, press the Left/Back key in the main menu.
2. Select "Mode" and confirm with OK.
3. Select "Torque" and confirm with OK.
4. Select "Indicating" mode and confirm with OK to measure the torque without
configuring further settings.
5. Select "Triggering" mode in order to configure further settings.
In "Triggering" mode, configure the following device settings and confirm with OK:
UNITS
TARGET VALUE
MIN TOLERANCE
MAX TOLERANCE
DIRECTION OF ROTATION
8.1.2.
Optional Functions
8.1.2.1.
Chargeable enabling of the angle of rotation function under
http://ho7.eu/holex-hct-angle
Tare
Do not move
Menu
3
4
2
16:32
Peak
back
MODE
Torque
Define the desired unit of measure for the torque.
Define the value of the target torque.
Define the lower tolerance limit for torque.
Define the upper tolerance limit for torque.
Define the direction of tightening.
Angle of rotation
16:32
0.0
Nm
Peak
MENU
Mode
Connection
Settings
1/4

Publicidad

loading

Este manual también es adecuado para:

655025