MODE
Angle
Menu
1. If a password is required, press the Left/Back key in the main menu.
2. Select "Mode" and confirm with OK.
3. Select "Angle" and confirm with OK.
Configure the following device settings and confirm with OK:
UNITS
Define the desired unit of measure for the torque.
SNUG TORQUE
Define the value of the snug torque.
TARGET ANGLE
Define the value of the target angle.
MIN TOLERANCE
Define the lower tolerance limit for angle of rotation.
MAX TOLERANCE
Define the upper tolerance limit for angle of rotation.
DIRECTION OF ROTATION
Define the direction of tightening.
8.2.
HISTORY
i
History can be accessed via Hoffmann Group - Connected Tools (HCT) App
9.
Connection
MENU
16:32
Mode
0.0
Connection
Nm
Settings
back
1/4
Menu
Peak
1. If a password is required, press the Left/Back key in the main menu.
2. Select "Connection" and confirm with OK.
3. Select Bluetooth "ON".
4. For connection to a computer: Select HID "ON" and configure the following set-
tings:
Reset Bluetooth
App
Traceability
HID
Value separator
Data set separator
Nr. Separator
Keyboard lang.
Unit
Sign
9.1.
CONNECTING TO A SMARTPHONE VIA QR CODE
1. Display the QR code on the torque wrench.
2. Scan the QR code using the Hoffmann Connected Tools app.
▶ The torque wrench is now connected to the app.
9.2.
CONNECTING TO A SMARTPHONE OR COMPUTER USING
BLUETOOTH
1. For a connection to a smartphone: Load the Hoffmann Connected Tools app.
2. Search for devices using the app or computer.
▶ Nearby Bluetooth devices are displayed.
3. Select the device (HCT-TW...).
▶ The torque wrench is now connected to the app or computer.
CONNECTION
Bluetooth
ON
Resetting Bluetooth
OFF
QR code
SHOW
Menu
1/12
All existing Bluetooth connections, in-
cluding the linked connections, must be
delimited.
Activate the Bluetooth connection to the
app.
Secure data transmission mode to the
app.
Activate the Bluetooth HID connection to
the PC or mobile device.
Set the delimiter for separating the val-
ues and units when transferring to a
computer. Delimiter dependent on pro-
gramme used.
Set the delimiter for separating the indi-
vidual data sets when transferring to a
computer. Delimiter dependent on pro-
gramme used.
Set the decimal delimiter symbol for
measurement values. The delimiter is de-
pendent on computer keyboard lan-
guage.
Set the computer keyboard language.
Set whether the unit is to be transferred.
Set whether the sense sign (+/-) for the
direction of rotation is to be transferred.
10. Operation
10.1.
SETTING THE EFFECTIVE LENGTH
16:32
0.0
Nm
Menu
Peak
Measurement mode
SETTINGS
MENU
Display
Mode
Measurement
Connection
System
Settings
Menu
back
1/4
back
i
Where an extension is used, the effective length must be adjusted. Standard effect-
ive length 0.0 mm.
ü Extension installed flush with the reversible ratchet.
1. If a password is required, press the Left/Back key in the main menu.
2. Select "Settings" and confirm with OK.
3. Select "Measurement" and confirm with OK.
4. For "Effective length", enter the effective length of the extension:
Effective length
10.2.
TIGHTENING PROCEDURE
ü Desired measurement mode is set; correct settings configured.
ü Hexagon socket firmly attached to torque wrench and locked into place.
1. Set tightening direction via the reversing level on the reversible ratchet in ac-
cordance with the settings configured in the measurement mode.
2. Apply the torque wrench at right angles to the nut or bolt.
3. Apply force to the centre of the handle tangentially to the swivel radius until the
desired torque or angle of rotation is reached.
▶ The current torque value/angle of rotation value is displayed.
▶ When the set torque value/angle of rotation value is reached, the current
value is shown in green.
CAUTION! Once the desired torque/angle of rotation is reached, end tight-
ening procedure immediately.
4. Confirm the value using the Send button in order to continue with the next tight-
ening procedure.
10.3.
CORRECTING SCREW CASES THAT WERE NOT PERFORMED
CORRECTLY
i
For triggering mode.
1. If a screw case was not performed correctly:
▶ Torque wrench indicates that operation was not performed correctly and
asks whether you wish to repeat the procedure.
2. To repeat the process, confirm by pressing the Right function button.
3. Loosen screw and check workpiece for damage.
4. If necessary, repeat tightening procedure with a new screw.
▶ The incorrectly performed screw case is saved and marked red in the History
field on the app.
10.4.
TRANSFERRING DATA TO A SMARTPHONE OR COMPUTER
10.4.1.
Transfer data to app via Bluetooth
ü Torque wrench connected to the Hoffmann Connected Tools app via Bluetooth.
1. All settings and data are transferred automatically to the app.
2. History can be exported as a CSV file via the app.
10.4.2.
Transfer data to computer via Bluetooth HID
ü "Connection" shows that "HID" is activated.
ü Corresponding program (for example spreadsheet program) opened and cursor
placed in correct position.
1. Connect torque wrench with computer via Bluetooth.
2. After tightening procedure, press send button.
▶ Values are transferred to the program.
10.5.
SWITCHING OFF TORQUE WRENCH
1. Press OK for longer than three seconds.
▶ Torque wrench switches off.
11. Settings
Measurement mode
16:32
MENU
0.0
Mode
Connection
Nm
Settings
Menu
Peak
back
1/4
back
MEASUREMENT
Unit
Nm
Threshold
75%
Evaluation time
5 sec
Settings
1/8
SETTINGS
Display
Measurement
System
Menu
www.hoffmann-group.com
de
en
bg
zh
da
fi
fr
it
hr
lt
nl
no
pl
pt
ro
sv
sk
sl
es
cs
hu
13