Descargar Imprimir esta página

Mitsubishi Electric Mr.SLIM SLZ-M FA Serie Manual De Instalación página 15

Ocultar thumbs Ver también para Mr.SLIM SLZ-M FA Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95
7. Electrical work
Function table
Select unit number "Grp." [table 1]
Mode
Power failure automatic recovery
Indoor temperature detecting
Smart Defrost *4
Select unit numbers 1 to 4 or "All"
Mode
Filter sign
Fan speed
Up/down vane setting
3D i-see Sensor positioning *3
Fan speed during the cooling thermostat is OFF
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
*3 When the 3D i-see Sensor corner panel position changed, change this mode. Refer to page 21.
*4 It is available when the indoor unit is connected to any of the particular outdoor units.
7.3.3. How to set the fixed up/down air direction
• Only the particular outlet can be fixed to certain direction with the pro-
cedures below. Once fixed, only the set outlet is fixed every time air
conditioner is turned on. (Other outlets follow UP/DOWN air direction
setting of the remote controller.)
I Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to each
air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
• "Up/Down air direction" is the direction (angle) to fix.
Reset
1
2
horizontal
Horizontal airflow
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Available
Not available
Settings
100Hr
2500Hr
No filter sign indicator
Silent
Standard
High ceiling
Not setting
Draft-less setting (vanes angle setup 1)
Downward setting (vanes angle setup 2)
Position 1 ("
" stamp position, page 21)
(Position 1)
Position 3 ("○" stamp position, page 21)
Setting fan speed
Stop
Extra low
3
4
5
Downward
Fixed setting
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be fixed
horizontally to avoid direct airflow.
Mode no.
01
*1
02
20
Mode no.
07
08
11
12
27
Electric component box
Outlet No. 4
Outlet No. 3
Note:
The outlet No. is indicated by the number of grooves on both ends of each
air outlet. Set the air direction while checking the information shown on the
remote controller display.
Air outlet identification marks
Setting no.
Initial setting
setting
1
2
Ο
*2
1
Ο
2
3
1
Ο
2
Setting no.
Initial setting
setting
1
2
Ο
3
1
2
Ο
3
1
2
Ο
3
1
2
3
Ο
1
2
3
Ο
Outlet No. 1
Outlet No. 2
13
en

Publicidad

loading