Descargar Imprimir esta página

Mitsubishi Electric Mr.SLIM SLZ-M FA Serie Manual De Instalación página 16

Ocultar thumbs Ver también para Mr.SLIM SLZ-M FA Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95
7. Electrical work
Select:
F1
en
If all outlets are selected,
next time the unit goes into operation.
Navigating through the screens
• To go back to the Main menu ..........[MENU] button
• To return to the previous screen .....[RETURN] button
Input display:
F1
Return:
F1
Return:
14
Manual vane angle
Outlet
Angle
F2
F3
F4
Manual vane angle
Setting
will be displayed the
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Cur.
Address
Check
F2
F3
F4
Manual vane angle
Ref. address
Unit No.
Function setting for unit
with vane fully open.
F2
F3
F4
Manual vane angle
No communication
Check Unit state.
F1
F2
F3
F4
The current vane setting will appear.
Select the desired outlets from 1 through 4 with the [F1] or [F2] button.
• Outlet: "1", "2", "3", "4", and "1, 2, 3, 4, (all outlets)"
Press the [F3] or [F4] button to go through the option in the order of "No setting (re-
set)", "Step 1", "Step 2", "Step 3", "Step 4", "Step 5", and "Draft reduction*".
Select the desired setting.
■ Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All outlets
reduction*
* Draft reduction
The airflow direction for this setting is more horizontal than the airflow direction for
the "Step 1" setting in order to reduce a drafty feeling. The draft reduction can be
set for only 1 vane.
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4) when the
transmission is completed.
Make the settings for other outlets, following the same procedures.
Confirmation procedure
1 First, confirm by setting "Ref. address" to 0 and "Unit No." to 1.
• Move the cursor to "Ref. address" or "Unit No." with the [F1] button to select.
• Select the refrigerant address and the unit number for the units to whose vanes
are to be fixed, with the [F2] or [F3] button, and press the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm the unit.
2 Change the "Unit No." in order and check each unit.
• Press the [F1] button to select "Unit No.".
Press the [F2] or [F3] button to change the "Unit No." to the unit that you want
to check, and then press the [F4] button.
• After pressing the [F4] button, wait approximately 15 seconds, and then check
the current state of the air conditioner.
→ The vane is pointing downward. → This air conditioner is displayed on the
remote controller.
→ All outlets are closed. → Press the [RETURN] button and continue the opera-
tion from the beginning.
→ The messages shown to the left are displayed. → The target device does not
exist at this refrigerant address.
• Press the [RETURN] button to return to the initial screen.
3 Change the "Ref. address" to the next number.
• Refer to step 1 to change the "Ref. address" and continue with the confirmation.
Step 2
Step 5

Publicidad

loading