If the installation of the toilet requires the use of through-hull
valves below the waterline, it is essential to follow the fitting
instructions provided by the manufacturer of the through-hull
valve.
Access to the valves should be easy for all users of the toilet.
If this is not the case, additional full flow marine quality valves
should be installed on the water inlet and outlet.
DANGER
Ö All vented loops (not supplied with the toilet) must be
installed a minimum of 50 cm above the waterline.
DANGER
Improper installation, defective condition of the
pipes.
Risk of flooding.
Ö Ensure that the pipes are in good condition.
Ö Check that there are no leaks.
Ö The use of a ventilated loop between the pump and
the bowl is compulsory.
NOTICE
Risk of contamination of the toilet water, damage to
the blade.
Ö Make sure that the two through-hull fittings: those
for the sea water supply and for the soil water outlet
are not too close together.
3.4 FITTING THE SWITCH/BUTTON/PANEL
• Choose a location that is easy to reach from the toilet bowl.
3.4.1 COMFORT VERSION
• Cut out a 40 mm x 25 mm rectangular panel.
• Fix the holder supplied in place with screws.
• Insert the switch.
3.4.2 PLUS AND PREMIUM MODELS
• Drill out a 33 mm hole in the bulkhead.
Note: On some models the push button can be placed on the
bowl.
• Plus Model: Connect the plastic tube to the pushbutton.
• Insert the pushbutton and screw on the locknut supplied.
3.4.3 LUXE MODEL
Cut out a rectangle measuring 80x50 mm from the bulkhead.
The control panel must be fitted in a position where it does
not interfere with use of the seat and cover, and it must not be
placed more than 1.50 m from the electrical control box.
3.5 ELECTRICAL CONNECTION
DANGER
The electricity supply to the Sanimarin®
must be connected directly to the boat's
electrical switchboard, and it must be used
solely for that equipment. It is advisable to
add a 25 A fuse in a 12 Volt system, and a 15
A fuse in a 24 Volt system.
NOTICE
Ö It is essential to observe the wiring diagram in the
enclosed instructions.
3.5.1 ADVICE FOR WIRING UP THE SANIMARIN®
Connect the electrical box to the battery, making sure that the
cross-section of the wires is sufficient.
Maximum
recommended
voltage drop (5%)
Electricity
consumption per
second
Current consumption
300 W / 25 A
/ Fuses
Electric diameter wire 1.5 mm
2.5 mm
4 mm
6 mm
12 V
24 V
0.6 V
1.2 V
0.007 Ah
0.004 Ah
360 W / 15 A
= 1 m max
1.5 mm
= 3.5 m max
2
2
= 2 m max
2.5 mm
= 6 m max
2
2
= 3 m max
4 mm
= 9.5 m max
2
2
= 4.3 m max
6 mm
= 14 m max
2
2
3.5.2 WIRING THE TWO-POSITION SWITCH (COMFORT MODEL)
Wire up the switch as shown in the attached leaflet.
3.5.3 FITTING THE CONTROL BOX PREMIUM, PLUS AND LUXE MODELS)
Fix the control box in a dry, protected location.
DANGER
Electric risk !
Ö Do not connect battery, power source in to
the control panel connection on the control box.
Insert and connect the electrical wiring from the Sanimarin® to
the control box.
NOTICE
Ö Wire up the control box as shown in the attached
leaflet, always noting the colors.
Ö Red
wire
=
-MACERATOR (see attached leaflet).
Lastly, connect the control box to the battery, making sure that
the cross-section of the wires is sufficient (POWER SOURCE
location).
3.5.4 CONNECTING THE BLACK WATER TANK
Connect the tank high level sensor to the control box, at the
TANK FULL SIGNAL location.
3.6 FINALIZING THE BUTTON/PANEL ASSEMBLY
3.6.1 CONNECT THE BUTTON TO THE CONTROL BOX
• Plus Model: Connect the other end of the tube to the control box.
• Premium Model: Connect the other end of the wire to the
control box (CONTROL BUTTON location).
3.6.2 CONNECT THE CONTROL PANEL TO THE CONTROL BOX
Fix the control panel in a horizontal position and clip the frame
into place.
Connect the wires to the Control box (CONTROL PANEL
location).
4. COMMISSIONING
• Power on.
• Open the water admission valve fully to ensure a good
bowl rinse.
Plus, Premium, Luxe models:
• Press Normal button.
• Throw several sheets of toilet tissue into the bowl and repeat
the cycle. The bowl should completely clear.
• Test the Eco cycle pressing the Eco button.
• Throw several sheets of toilet tissue into the bowl and repeat
the cycle.
• Make sure that there are no leaks on the water circuits, at the
inlet and at the outlet.
• Make sure the water drains properly.
Comfort model:
• press ADD WATER until the water level is about halfway up
the bowl (about 6 sec).
• Put some pieces of toilet paper in the bowl,
• Press PUMP OUT (about 6 sec)
• and then press ADD WATER (about 4 sec).
Note: We recommend compliance with the time lapses shown
above.
• Make sure that there are no leaks on the water circuits, at the
inlet and at the outlet.
• Make sure the water drains properly.
5. USE
Only the disposal of toilet paper, faecal matter, and waste
water will be covered under the guarantee.
Any damage due to foreign bodies such as cotton,
condoms, sanitary towels, wet wipes food, hair, or
liquids such as oils, solvent products,... will invalidate the
guarantee.
NOTICE
Ö In the event of a long interruption of electricity, the
water and electricity supplies to the Sanimarin® should
be switched off (see procedure in «Wintering»).
Note : In rough seas, empty the bowl (using the pump out
position) to avoid spillage.
11
+MACERATOR,
black
wire
EN
=