SPARK PLUG CHECK
Most common problems when starting a machine are caused by a dirty spark plug or in poor condition. Clean the
spark plug and check it regularly. Check that the gap between electrodes is correct (0.6-0.7mm).
TROUBLESHOOTING
Good maintenance will extend the service life of your machine. Extended or constant use may require more intensive
maintenance so that the machine continues to work properly. The table includes some of the most common problems,
their cause and solution. If the machine does not start:
If the machine does not start, check the compression of the engine and the spark of the spark plug. Depending on the
symptoms we list here some probable causes and solutions:
SPARK
CYLINDER
PLUG
COMPRESSION
WORKS
IS NORMAL
PROPERLY
Yes
Yes
Yes
No
Lack Of
Compression
Yes
The Engine Does
Not Turn
POSSIBLE CAUSE
There is no fuel in the fuel tank
The fuel filter is dirty
There is water in the fuel
The fuel type used is not adequate
The carburettor is dirty
The spark plug pipe is not properly
connected
The spark plug is dirty
Engine switch does not work
The spark plug is loose
The piston and the segments are
worn
The cylinder is scratched
Seized engine
Electrical problem in the engine
SOLUTION
Refill with fuel
Clean the filter
Replace it
Change the fuel to one with an adequate
octane rating
Take your machine to the Official Service
Connect it
Clean the spark plug
Take your machine to the Official Service
Tighten it
Take your machine to the Official Service
Take your machine to the Official Service
Take your machine to the Official Service
Make sure the switch is in the ON position.