USER INSTRUCTIONS
– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct action.
Apply only to qualified technical personnel.
– Boiler installation and any other assistance and/or maintenance activity must be carried out by qualified personnel per-
suant to Standard CEI 64-8. Under no circumstances, the devices sealed by the manufacturer can be tampered with.
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is installed.
– The manufacturer shall not be held liable for any damage caused by improper use of the appliance.
– T his appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
LIGHTING AND OPERATION
KEYS LOCK: if the device is not used, the keys will be locked 15 minutes after the last setting was made (PAR 5 by
default) and the display light switches off.
To set one of the operating modes, press any of the keys for more than two seconds (the display will indicate one to
four segments progressively before unlocking the controls).
BOILER IGNITION (fig. 25)
The first ignition of the boiler must be car-
ried out by qualified technical personnel.
Successively, if it is necessary to start up
the boiler again, adhere strictly to the fol-
lowing instructions: open the gas tap to
allow the flow of the fuel and move the main
switch of the system to "ON".
After a stop, wait for about 30 seconds
before restoring functioning conditions do
that the boiler can perform the control
sequence.
If the green led is on, this indicates the pre-
sence of voltage.
ATTENTION: for set up modality of function more adapted to graze the keys simply. One
beep indicates that the boiler has taken command. If PAR 5 is disabled, the display
remains lit.
WARNINGS
Winter
Press the key
of the controls to activa-
te the winter mode functioning (heating and
D.H.W.). The display will be as shown in the
figure.
Summer
Press the key
of the controls to activa-
te the summer mode functioning (only the
production D.H.W.). The display will be as
shown in the figure.