5. The charger will not charge if the battery pack is too hot
or too cold. The charger will show a flashing yellow LED
and wait until the battery temperature is between 32°F
(0°C) and 113°F (45°C) to begin fast charging.
6. Standard fast charging time is 55 minutes. Charger may
take longer than 55 minutes. The charge cycle may be
longer if the battery has been left in a low state of charge
for an extended period of time. When the charge is
complete, all 4 green LED's stay illuminated.
7. A flashing red LED indicates the battery is faulty and the
charger will not charge. Remove the battery from the
charger and replace the battery.
Battery Pack
Battery Pack Protection
To maximize performance and battery life, the Lithium-
Ion battery is protected by safety circuits in the tool and
the charger. They monitor battery voltage, discharge/
charge amperage and temperature. See overloading
section of this manual for more information.
Cold Weather Operation
The Lithium-Ion battery can be used in temperatures
down to -4°F(-20°C). When the battery pack is very cold,
run the tool at no load to warm the battery and then use
the tool normally.
Hot Weather Operation
If the Lithium-Ion battery temperature reaches 158°F
(70° C), the protection circuit will turn off the battery and
the 2 white LED's on the tool will flash. Once the battery
has cooled down, the tool will resume normal operation.
Storage
Do not expose your battery pack to water or rain; this
could damage the battery pack.
Fully charge the battery before placing it in storage. For
optimum life, store the all Lithium-Ion batteries at room
temperature away from moisture. Permanent capacity
loss can result if batteries are stored for a long period at
high temperature.
ZCTG861CE Rev. A
Maintenance
Service
Service of a tool requires extreme care and knowledge.
Service should be performed only by a qualified service
technician.
• Always check tool for damaged parts before use.
• Replace or repair damaged parts before use. Check
alignment of moving parts. Binding of moving parts or
broken parts may alter operation.
• Have damaged parts properly repaired or replaced by an
Authorized Service Center.
• Do not use tool if switch does not turn it on and off.
• Maintain tools. Keep tools dry, clean and free of oil and
grease for better and safer performance.
• For the location of the nearest Snap-on repair center, call
Snap-on customer service at 1-888-382-6522.
• When charging or discharging a lithium-ion battery over
a short period of time, the internal temperature of the
battery pack increases substantially. This is normal.
• Under ideal working conditions the useful life of a lithium-
ion battery pack is around 1000 charge/discharge cycles.
Improper care and maintenance shortens battery life and
the amount of time the battery holds a charge.
• Use only with Snap-on charging equipment that specifies
a CTB series battery pack.
• Avoid short circuiting the battery pack. Permanent
damage to the pack can occur from high current
discharge.
• Unplug charger from outlet before starting the
disassembly procedure.
• Remove the battery pack from the tool before starting
the disassembly procedure. Short-circuiting the
battery pack can cause fire or personal injury.
• Use safety equipment. Always wear eye protection.
For service, warranty or operational questions
call 1-888-382-6522.
For warranty service please send the instrument
to:
Snap-on Meter Repair
9615 SW Allen Blvd. Ste 104
Beaverton, OR 97005
Certificate of Calibration is available upon
request as a separate charge. Please call 1-888-
382-6522 before sending the instrument with a
request for certificate of calibration to:
Snap-on Meter Repair
9615 SW Allen Blvd. Ste 104
Beaverton, OR 97005
10
(01/19)

Publicidad

loading