Installation Instructions
INSTALLATION—RECIRCULATING
[6 | CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARN
| N G: If house wiring is not 2-wire
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
« Remove the 6 screws on the junction box cover
and the knockout on the top or left side.
Junction
box cover
¢ Secure the house wiring to the junction box with
a strain relief.
_
4
a
* Connect the white lead to the branch circuit white lead.
* Connect the black lead to the branch circuit black lead.
* Connect the green/yellow lead to the branch
circuit green lead or bare ground lead.
¢ Secure all the connections with wire nuts on each
electrical connector.
¢ Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
¢ Secure the junction box cover with the 6 original
Screws.
17
INSTALL DUCT COVERS
« Remove protective plastic
covering.
e Place the decorative duct
covers on top of the hood.
NOTE: The inside piece has vent
holes on one end intended for
use when the hood is installed
for recirculating purposes. Be
sure the vented end is at the top;
the vent holes will be visible in
this installation.
Mounting
screws
Vent holes
The inside duct piece must slip
into the folded ends on the outer section.
Be
Ba
Duct cover
Upper
support bracket
duct cover
Lower duct
cover
Duct attachment
tabs
Lower duct
cover seat
¢ Extend the inner duct upward to the ceiling
bracket.
* Press up on the front corners of the filter cover panel
to unlock. Lower the panel to access the filter.
e Locate the screw holes on the inside front edge
of the opening. Install 2 screws to secure the duct
cover to the hood.