Technical data
PTW 1500, PTW
3500
Power range
Maximum value at 100 % duty cycle
Pilot arc current
Voltage measurement (V-Peak)
Plasma gas/shielding gas (according to EN 439)
Cooling system
coolant
Cooling power
Min. coolant pressure
Max. coolant pressure
Minimum coolant flow rate
*) Liquid cooling
**) Original Fronius coolant
***) Lowest cooling power according to standard IEC 60974-2
The product conforms to the requirements of standard IEC 60974-7
Loading limits
For plasma welding, the values for the plasma gas flow rate and maximum welding cur-
dependent on the
rent must lie within the set limit values. An upper or lower exceed of these limit values
plasma gas flow
can change the plasma properties, e.g.:
rate
-
-
NOTE!
Do not exceed the lower limit values set for plasma gas values and max. welding
current during operation.
NOTE!
The minimum coolant flow rate is 1 l/min
This table is only valid for the PTW 1500
Plasma nozzle dia.
1.5 mm
2.0 mm
2.5 mm
24
lower rate of plasma gas flow -> "soft" plasma jet
high rate of plasma gas flow -> "hard" plasma jet ("plasma cutting")
PTW 1500
3 - 150 A
150 A
10 A
141 V
Argon
*)
**)
1000 W ***)
3.0 bar
43.50 psi.
5.5 bar
79.74 psi.
1.0 l/min
Plasma gas flow rate *
Min. 0.30 l/min
Max. 0.80 l/min
Min. 0.35 l/min
Max. 1.00 l/min
Min. 0.45 l/min
Max. 1.20 l/min
PTW 3500
3 - 350 A
350 A
30 A
141 V
Argon
*)
**)
1900 W ***)
3.0 bar
43.50 psi.
5.5 bar
79.74 psi.
1.0 l/min
Max. welding current
60 A
100 A
80 A
120 A
110 A
145 A